Description
Aims CON120AC1224VDC – AC Converter / Battery Charger 12V & 24V Smart Charger 75 Amps – Listed to UL 458/CSA
Why Not Buy A Charger That Can Charge Both 12 and 24 Volt Battery Systems?????
Perfect For Industrial Applications Like Aerial Lifts, Floor Scrubbers, Small Fork Lifts,
Key Features
- Large charging capacity design (75 Amp for 12Vdc; 37.5 Amp for 24Vdc) charges a 100 amp hour battery in under an hour up to 90% charge
- Power supply up to 75 amps at 12Vdc or 37.5 amps at 24Vdc
- Three stage smart charger with variable charging voltage algorithm for maximizing battery life (bulk, absorb and float)
- 4 pre-programmed charging algorithms using the dip switches for the most common charging profiles
- Charges lead acid, AGM, GEL and LiFPO4 batteries
- Adjustable charge current control dial to safely charge smaller battery (s)
- Wide input voltage range, 70Vac to 145Vac for unstable inputs
- Reverse polarity, over voltage, under voltage, short circuit, over temperature protections
- High AC to DC converting efficiency design >80%
- Smart fan, always on for maximizing charger performance
- Includes battery temperature sensor port to help maintain the life of the battery(s) (battery temperature sensor not included)
- AC input cord – 4ft
- Listed to UL 458 and CSA 22.2 NO. 107.1
- 2 Year warranty
Specifications:
Input Voltage | 96-145VAC full performance |
70-96VAC automatically de-rate to 50% of full load current | |
Frequency | 40Hz to 70Hz |
Nominal Input Current at Rated Output | <9Aac |
Voltage Measurement Accuracy | ±8Vac |
Frequency Measurement Accuracy | ±1Hz |
Output | |
Nominal Voltage | 12/24Vdc manual adjustable |
Output Current | Input voltage 96-145V,
output current 75A for 12V mode output current 37.5A for 24V mode |
Input voltage 70-96V,
output current 37.5A for 12V mode output current 18.75A for 24V mode |
|
Rated Output Current | Manual adjustable |
Current Accuracy | ± 6% of full rated output current @25°C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit setpoint. |
Load Regulation | 1.5% |
Current Limit | 75-80Amp |
Dead-Battery Charging | 8-14.9Vdc at 100% of rated output current |
8-29.8Vdc at 100% of rated output current | |
Selectable Battery Type | Open Lead-Acid, Gel, AGM, LiFePo4, adjustable |
Parallel Outputs | Maximum of two AC converter units connected in parallel |
Efficiency | 80% |
Protection | |
Input Over Voltage | Unit is safe for input voltage up to 150VacRMS (and up to 215Vpeak). Above this level the damage may occur. |
Reverse Battery Polarity Protection | Non-destructive reverse battery polarity protection with fuses. Permanent damage will not occur and perform after fuse replacement. |
Input Under-voltage | No permanent damage for input voltages from 0-300Vac. Shutdown or input current limit or other means may be applied when input voltage is out of normal operating range. |
Output over voltage
12/24V mode |
12Vdc. Unit will shut down if Vcharging > Vcharging (target) + 1.0Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
24Vdc. Unit will shut down if Vcharging > Vcharging (target) + 1.5Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
|
Charger over temperature protection | The internal temperatures of the charger will be measured by NTC. Based on these measurements, unit will shut down if the temperature exceeds 105°C. Unit will restart when environment temperature cools to 95 °C. |
BTS(Battery Temperature Sensing) | The battery temperature sensor allows the charge controller to
continuously adjust charge voltage / charge current based on actual battery temperature. When the battery temperature is over 40 °C, unit will reduce the charging voltage to Float voltage, also it will reduce the Max charging current by 10% with every two degree of temperature rise. When the battery temperature is over 50 °C, unit will shut down. |
Environmental | |
Operation temperature | Nominal ambient temperature: 25°C
Operating Ambient Temperature range: -10°C to 40°C (On the heat sink of DC-DC part, if the temperature is over 90 ℃, the Charger Current will be de-rate to 50% ; if the temperature is over 105 ℃, the Unit will be shut down.) |
Relative humidity | 5~95% without condensation |
Noise | Unit requirements: below 50dB (A) measured at 1 m distance with fan full working. |
Storage Conditions Temperature | -20°C to +80°C |
Cooling | Fan always on, vented |
Safety | UL458,CSA22.2#107.1 |
Mechanical | |
Dimension (D x W x H) mm | 10.25” * 6.75” * 3.25” |
Unit Weight | 6.5 lb |
Boxed Weight | 7 lb |
Reviews